When you have an issue with your HVAC or plumbing, you want a company that you can trust. For the Creve Coeur area, our team is the answer. We’ve been servicing the Creve Coeur area since 1926, building a reputation for good work and good people.
Our work includes HVAC and plumbing services for commercial properties, homes, and 24 hours a day, 7 days a week emergency repairs. We’ve been making people comfortable since 1926 and would love to do the same for you.
Reliable Air Conditioning
While the cold snaps can be bone-rattling, the heat waves in Creve Coeur can be sweltering. To keep your home prepared for the hottest months of the year, our team offers the following AC services:
- AC repair: Whether your system won’t turn on or struggles to maintain a desired temperature, our team can inspect your system and resolve any repair needs.
- AC maintenance: Just like heating, your AC unit will be the most optimized if you have regular maintenance conducted. Our team can schedule maintenance, give you discounts, and offer additional perks when you sign up for the Planned Maintenance Agreement.
- AC installation: Need a new system or want to upgrade? Our team can help you select the best fit and install the system.
Although we work on central AC systems, that isn’t where our scope ends. Our team can also perform AC services on ductless air conditioning units and help improve indoor air quality.
If you want a free estimate on AC services for your Creve Coeur, MO, home, call (314) 329-1943 or contact us online.
(314) 329-1943Expert Heating
The last thing you want is to be stuck with no heating during a cold snap. Luckily, our team has a full suite of heating services to keep your home running strong. Our heating services include the following:
- Heating installations: With the many different heating options available, our team can help you install a new heating system or replace an existing one in your home.
- Heating maintenance: To get the most out of your heating system, you should have maintenance done at least once a year. If you want to get a tune-up without the hassle of scrambling to find an appointment, our Planned Maintenance Agreement could be an excellent fit for you.
- Heating repairs: If you feel that your heating system isn’t performing to your standards, our technicians can take a deep dive into the issue and fix any problem that could be taking place.
With how much variety exists for heating systems, our team is knowledgeable about many systems. Our team can perform heating services on boilers, furnaces, and heat pumps.
Classic Aire Care can handle all your Creve Coeur, MO, heating needs. Request a free estimate by contacting us online or calling (314) 329-1943
Top-Rated Plumbing
The plumbing system in your home can include many things. With how many items fall under plumbing, your home could collapse if your plumbing malfunctions. Luckily, the team here at Classic Aire Care is here for you.
We offer an extensive set of plumbing services. Whether you need plumbing installation, water heater services, plumbing repairs, drain cleaning, or anything in between, we’re here to help you.
To schedule plumbing services with Classic Aire Care in Creve Coeur, MO, contact us online or call (314) 329-1943
Why Choose Classic Aire Care?
We didn’t make it over 90 years by providing subpar work. Our NATE-certified technicians will give you high-quality work and ensure we leave your home better than we found it. But you don’t have to take our word for it. Instead, check out what our previous customers have had to say about their experience with us.
Classic Aire Care is the answer for any HVAC or plumbing service in Creve Coeur, MO. Schedule an appointment by calling (314) 329-1943 or contacting us online.
FAQs
Why is my AC running but not cooling?
It is a sign that you need repair work done. Chances are that something has malfunctioned with your condenser coil, which is something a professional can fix.
How do I choose a new furnace?
The needs of your home will dictate what option is best for your home. An HVAC technician can inspect your home, identify your needs, and help you select a furnace that will fulfill your needs.
Is it normal to smell gas from the water heater?
No, it is not. If you smell gas from your water heater, turn off the gas valve and schedule an appointment with an HVAC company.
Recent Jobs and Reviews in Creve Coeur, MO
Job Locations and Reviews
Responded to callback for residential cooling system not activating. Upon arrival, inspected electrical breaker panel serving HVAC equipment. Found tripped circuit breaker supplying power to outdoor condensing unit. Reset breaker, verified proper voltage supply, and confirmed system restored to normal cooling operation. Advised homeowner to monitor system performance and contact for service if breaker trips again, as repeated tripping may indicate underlying electrical or compressor issues requiring further diagnosis.
Responded to callback regarding excessive condensation and black mold growth on recently installed dual-zone AC system located in basement. Upon inspection, discovered improper condensate drainage from indoor air handler unit causing water accumulation beneath equipment. Identified clogged or improperly pitched condensate drain line with visible biological growth and debris buildup in PVC drain fittings. Observed frost accumulation on refrigerant lines indicating potential airflow restriction or low refrigerant charge contributing to excessive condensation. Cleared condensate drain blockage, verified proper drainage flow, and addressed penetration sealing around copper refrigerant lines where moisture intrusion was occurring. Recommended follow-up mold remediation for affected areas and monitoring of system operation to ensure condensate management functions properly.
Completed preventive maintenance tune-up on two residential cooling units located on side of home. Performed comprehensive system inspection including blower motor assembly, electrical connections, and air filtration components. Replaced air filter showing dust accumulation, verified proper motor operation, inspected wiring harnesses and ground connections, and confirmed all mechanical components operating within manufacturer specifications.
Completed on-site electrical estimate for generator installation at residential property. Evaluated existing electrical infrastructure including main service panel with adequate breaker capacity and circuit organization, and assessed gas meter location and utility connections for generator placement compatibility. Documented site conditions and equipment specifications to provide comprehensive estimate for standby generator system installation.
Responded to no cooling complaint on 10+ year old attic-mounted system. Upon inspection, discovered refrigerant leak in attic unit and confirmed outdoor condenser fan motor failure. Identified Lennox condenser unit with inoperative fan motor and low refrigerant charge due to active leak in evaporator coil. Provided repair estimate for refrigerant leak repair, system recharge, and condenser fan motor replacement to restore cooling operation.
Replaced defective evaporator coil under warranty on residential Lennox furnace system located in utility closet. Uninstalled existing furnace unit to access and remove failed coil, installed new evaporator coil (S/N T22A04858), reassembled system, and verified proper heating and cooling operation upon completion.
Responded to service call for thermostat malfunctioning with erratic behavior and temperature settings resetting randomly. Inspected Lennox system control board and wiring connections at hallway unit, verified all terminal connections on blue control module including 12VDC COMM/BUS terminals and R, A, B, and ACC1/ACC2 points. All wire connections were secure with proper voltage readings confirmed at +12V, A, B, and -12V terminals on the communication interface panel.
Responded to service call for 8-year-old Lennox system displaying "GF HSI SENSED OPEN" fault code on hallway thermostat. Accessed furnace control board and inspected hot surface igniter circuit and associated wiring connections. Diagnosed faulty sensor connection, performed necessary repairs to ECM drive control board terminals, and cleared fault code. Verified system operation and confirmed thermostat returned to normal heating and cooling functionality with proper communication to control board.
Responded to service call for reported humidifier leak in upstairs closet. Upon inspection, identified active water leakage from humidifier supply line connections causing visible ceiling staining and discoloration in adjacent areas. Discovered corroded PVC pipe joints with rust-colored staining at multiple connection points beneath the humidifier unit, indicating prolonged moisture exposure and deteriorated seals. Documented water damage evidence on ceiling surfaces near HVAC register and compromised plumbing connections. Provided customer with repair recommendations and photographed affected areas for documentation purposes.
Responded to reported electrical outage affecting kitchen and balcony outlets with sparking at circuit breaker panel located in basement. Inspected electrical panel, identified and replaced faulty circuit breaker that exhibited signs of arcing and heat damage. Tested affected outlet circuits in kitchen and balcony areas to verify proper voltage and functionality. All circuits restored to normal operation with no further signs of sparking or electrical hazards.
Installed decorative bronze chandelier with crystal accents in residential interior space, featuring cylindrical metal frame with leaf motif details and multiple candelabra-style bulbs. Secured fixture to ceiling mount with chain suspension system, verified proper electrical connections, and confirmed all lighting elements functioning correctly upon completion.
Responded to no cooling call on 4-year-old outdoor condensing unit that was not kicking on. Upon arrival, performed diagnostic evaluation of the system including electrical components, capacitor, contactor, and thermostat communication. Unit was found to be non-operational due to identified component failure requiring repair.
Responded to no cooling call on Trane system affecting entire home. Upon inspection, diagnosed failed dual run capacitor preventing compressor and condenser fan motor operation. Replaced defective capacitor with proper OEM-rated component, verified all electrical connections, and tested system operation. Unit restored to full cooling capacity with normal amperage draws and proper refrigerant pressures confirmed.
Replaced air filter X0581 on HVAC system and provided customer with an additional replacement filter for their next scheduled maintenance visit. Old filter was removed and disposed of properly. System confirmed operational for both heating and cooling functions.
Responded to return service call to replace defective wet switch on HVAC system. Upon arrival, confirmed presence of moisture and water staining on unit components as documented by previous technician. Removed failed wet switch and installed replacement part sourced from supply house. Verified proper operation of safety switch and confirmed system heating and cooling functions operating normally. Disposed of defective component and cleared unit for service.
Responded to water leak complaint from HVAC unit in storage closet affecting downstairs neighbor's unit. Upon inspection, discovered significant rust-colored corrosion and moisture accumulation between cylindrical equipment components, with visible dampness and crusty buildup on metal surfaces indicating active water intrusion. Documented equipment condition with photographs showing deteriorated areas, PVC drainage piping, and extent of corrosion damage requiring follow-up repair recommendations.
Replaced defective light fixture in residential setting and performed electrical system inspection. Verified proper circuit breaker operation and panel configuration to ensure safe electrical distribution throughout the property.
Replaced faulty 30-amp electrical disconnect box on HVAC system as part of new installation follow-up work. Installed new disconnect with fused pull-out assembly, verified proper wire connections to terminal block, and confirmed system operational for both heating and cooling modes.
Responded to report of AC unit leaking with water pooling in basement. Upon inspection, identified a crack in the condensate drain line causing water discharge onto basement floor. Repaired the damaged condensation line section to restore proper drainage and prevent further water accumulation. Unit confirmed to be cooling effectively with no refrigerant issues. Per customer instructions, system left with AC compressor off and fan operational only.
Responded to no cooling complaint on 4-month-old residential air conditioning unit blowing warm air. Upon inspection, found failed contactor preventing compressor operation. Removed defective contactor with burnt contacts and replaced with new component. Verified proper electrical connections at outdoor disconnect, tested system operation, and confirmed unit now cooling properly under first-year warranty coverage.